Home > Heat Pump System > GeoSimple
Household Geothermal Heat Pump System
- ¡°GeoSimple¡± is specially developed for household application of geothermal heat pump cooling & heating system.
- ¡°GeoSimple¡± has the capability of stable and easy operation by compact Water Core, Buffer tank and durable Double pipe type heat exchanger.
- Quality of ¡°GeoSimple¡± is certified by KS, Patents and using R-410A as eco-friendly refrigerant
- Advantage of ¡°GeoSimple¡± : Simple system, Easy installation, Stable and simple Water core, Safe and durable double pipe type heat exchanger.
► Components
¡°GeoSimple¡± has two kinds of model as GS-36, GS-60 with heating capacity from 11.4kw to 18.6kw and cooling capacity from 11.1kw to 18.0kw. It use R-410A and dimension is 600x750x600mm with 110~130kgs weight.
► Function of Components
Water Core
- Thermal water circulation and distribution by connection with underground heat exchanger
- Flushing and straining foreign objects
- Supplementary tank and Open type expansion tank
- Easy removal hose
- Guide plate for easy connection with under ground heat exchanger
- Single phase 220V, Tank capacity 40L
Heat Pump (GeoSimple)
Model : GS-36(10.5 kw), GS-60(17.5 kw)
- Cool & hot water supply for Cooling and heating
- Room controller for controlling Geosimple
- Double pipe type Heat exchanger
- Eco-friendly refrigerant R-410A
Buffer tank
Stable operation about load fluctuation for air conditioning
- Materials : Stainless steel(SUS-304)
- Capacity : 200L
- Diameter x Height : ¥Õ520*1519mm
- Thickness : 1.2mm
- Weight : 40kg
► Specification of GeoSimple, Water Core
GeoSimpe (Geothermal heat pump) |
Model Name |
GS-36 |
GS-60 |
Renewable Energy Korean Standards |
KS B 8292 |
Performance |
Heating Capacity |
kw |
11.4 |
18.6 |
Cooling Capacity |
kw |
11.1 |
18.0 |
Electricity Consumption |
Heating |
kw |
3.1 |
5.1 |
Cooling |
kw |
2.1 |
3.9 |
Electricity |
V, Hz |
3 Phase 4 Lines, 380V, 60Hz |
Refrigerant |
R-410A |
Compressor |
Type |
Scroll |
Starting Method |
Direct Input Starting |
Legal Refrigeration Capacity |
Tons |
1.06 |
2.14 |
Heat Exchanger (Load side) |
Type |
Double Pipe Type |
Circulation water amount |
LPM |
34 |
57 |
Connection pipe |
A |
25 |
25 |
Heat Exchanger (Geothermal side) |
Type |
Double Pipe Type |
Circulation water amount |
LPM |
34 |
57 |
Connection pipe |
A |
25 |
25 |
Dimension |
L*W*H |
mm |
600*750*600 |
600*750*600 |
Weight |
kg |
110 |
130 |
Safety Instruments |
High-Low pressure switch, Compressor overheating protection |
Water Core |
Electricity |
V, Hz |
Single Phase 2 Lines, 220V, 60Hz |
Weight |
kg |
20 |
23 |
Circulation water amount |
LPM |
34 |
57 |
Tank capacity |
L |
40 |
40 |
* Above specification are subjected to be changed for quality improvements without notification in advance